Compliance glossary

    Thorough Examination and Test (TET): what UK duty holders must know

    A **Thorough Examination and Test (TET)** — often written as **Thorough Examination** for LOLER items — is the statutory inspection every duty holder must arrange for lifting and other regulated work equipment. Here is the exact scope, frequency and evidence trail expected by the HSE.

    Statutory frequency

    Set by regulation 9 of LOLER 1998 and the equivalent PUWER scheme:

    • ▸Every 6 months — equipment used to lift people, and all lifting accessories.
    • ▸Every 12 months — other lifting equipment (cranes, forklifts, telehandlers, hoists).
    • ▸Before first use — after installation, relocation or major modification.
    • ▸After exceptional circumstances — accident, prolonged storage, weather damage, unauthorised modification.

    What the competent person examines

    The competent person carries out a visual and functional examination — structure, welds, hydraulics, controls, safety devices, load limiters, brakes, guarding — together with a proof-load or overload test where the written scheme requires it. Defects are classified as ‘imminent risk of failure’, ‘repair by a specified date’ or ‘observation’.

    Report of Thorough Examination (RTE)

    The output is a formal RTE that must be issued to the duty holder as soon as reasonably practicable, and no later than 28 days after the examination. Any ‘imminent risk’ defect must also be notified in writing to the enforcing authority (HSE or DVSA). Cloud VGP generates the RTE straight from the mobile app, e-signs it and pushes a defect notification when needed.