What is a Thorough Examination and Test (TET)?
A Thorough Examination is a statutory inspection required by UK regulations (LOLER 1998 for lifting equipment, PSSR 2000 for pressure systems, PUWER 1998 for machinery, PPE at Work Regs 2022 for Category III PPE, Work at Height Regs 2005 for fall protection). Its purpose is to verify the good condition of the equipment, its continued conformity and the effectiveness of its safety devices. It is distinct from maintenance — it records, it does not repair. It applies to every asset listed in the applicable ACOP, and produces a written report given to the duty holder and retained for a minimum period (5 years for LOLER lifting equipment, longer for other assets).
Which equipment must be thoroughly examined?
The main families are: lifting equipment and lifting accessories (cranes, hoists, FLTs, MEWPs, slings, hooks), work equipment and dangerous machinery under PUWER, Category III PPE against falls from height, pressure systems under PSSR, powered industrial doors and gates, storage racking. The exact list depends on the ACOP applicable to each family. Where doubt remains (e.g. a collaborative robot or a cobot), the duty holder refers to the manufacturer's manual, the risk assessment for the task and, where necessary, to a UKAS-accredited engineer surveyor.
What is the statutory frequency of a Thorough Examination?
It depends on the equipment and the applicable ACOP. As a guide: 6 months for equipment used to lift persons (MEWPs, suspended platforms) and for powered industrial doors, 12 months for most load-lifting equipment, all lifting accessories, Category III fall-arrest PPE and storage racking, 3 months for certain heavy-use machinery, 12 to 72 months for pressure systems under the written scheme of examination, and 6-monthly interim for public passenger lifts under LOLER. Frequency is shortened where use is intensive, where the environment is harsh (dust, moisture, corrosion) or after an incident. Cloud VGP calculates due dates automatically per family and site.
Who can perform a Thorough Examination?
It must be carried out by a competent person as defined in HSE guidance INDG422 and the relevant ACOPs. That may be an in-house appointed person with adequate training, an independent competent person, or an engineer surveyor from a UKAS-accredited body (a SAFed member such as Zurich, Allianz Engineering, HSB, Bureau Veritas or Applus+). Choice depends on risk, complexity and, in some cases, on a specific requirement — for instance PSSR revalidation of a pressure vessel typically requires a UKAS-accredited body. In every case, the person must hold the practical and theoretical knowledge, appropriate measuring equipment and enough independence from the user. The competent person carries professional liability for the report.
What must a compliant Thorough Examination report contain?
The report identifies the equipment (make, model, serial number, date brought into service, SWL/WLL), states the statutory reference of the examination performed, lists the points examined, records measurements (proof-load tests, safety-device tests), any defects graded by severity (existing, imminent or becoming so within a defined period), recommended dates by which defects must be rectified, the identity and competence of the person carrying out the examination, their signature and the date. Under LOLER reg 10 it must be given to the duty holder as soon as is practicable and, for defects becoming imminent, a copy sent to the enforcing authority (HSE or Local Authority). Digital records accessed by QR code speed up HSE and principal-contractor audits.
What is the difference between a TET, preventive maintenance and post-modification examination?
A Thorough Examination is a periodic statutory inspection that records the state of the equipment and the effectiveness of its safety devices. Preventive maintenance is a scheduled technical operation aimed at keeping the equipment in efficient working order (lubrication, changing wear parts, adjustments). A post-modification examination is a one-off check required after a significant change, major repair, accident or extended out-of-service period (LOLER reg 9(3), PUWER reg 6). The three cycles are complementary and must be recorded separately: a compliance platform separates them and triggers a fresh examination the moment a modification or incident is logged.
What is the risk of not carrying out statutory examinations?
An out-of-date Thorough Examination exposes the duty holder to cumulative risk. Under the Health and Safety at Work Act 1974 s.33, fines are unlimited and directors can face up to 2 years' imprisonment. The Sentencing Council guidelines set penalties by turnover: a Category A high-culpability breach at a large organisation can exceed £10m. Civil liability follows quickly through personal injury claims. The HSE can serve improvement or prohibition notices requiring immediate withdrawal of the equipment. Insurance cover for engineering breakdown or public liability may be void. And principal contractors in construction, industry and logistics almost always require Thorough Examination reports as a condition of access.
How does compliance software simplify Thorough Examinations?
It centralises the asset register, calculates statutory due dates by family, schedules campaigns automatically, lets in-house and external competent persons complete reports on mobile (offline included) with photos and signatures, and tracks defects to closure. Cloud VGP adds QR/NFC tagging to pull up an asset's full history in one scan, tamper-evident 10-year archives, one-click HSE-ready PDF export, multi-channel alerts, a multi-site dashboard and structured invoicing for external competent persons. From £0.36 per asset per month.