Stainless steel storage vessels
Statutory inspection, frequency and related regulatory watch
Everything you need to keep your stainless steel storage vessels compliant: frequency, statutory reference, competent bodies, documents to produce and recommended regulatory watch.
Frequency
Every 5 years
Statutory reference
PSSR 2000
Expected document
Inspection report + health & safety register
Main obligations
- Inspection every 5 years is mandatory (PSSR 2000).
- Initial inspection when commissioning or re-commissioning after a significant modification.
- Maintain a health & safety register in line with applicable UK HSE regulations.
- Retain reports for at least 5 years, and for the full asset lifetime for the initial inspection.
- Close out defects promptly and keep an auditable trail of corrective actions.
What our software automates
- Schedule and early alerts (T-60, T-30, T-7) for every asset.
- Checklists aligned with applicable UK regulations, signed electronically on mobile.
- Asset identification via QR code or NFC tag attached to the equipment (document pouch).
- Automatic generation of timestamped PDF reports and defensible archive.
- Defect tracking, repair costs and full CMMS history.
- Automatic updates when regulations change (built-in regulatory watch).
Recommended regulatory watch
Category 2
Pressure systems (PSSR)
The Pressure Systems Safety Regulations 2000 (PSSR) require the user to have a Written Scheme of Examination (WSE) drawn up by a competent person covering all relevant parts of the system, and to ensure the system is examined in accordance with that scheme.
Category 7
Storage tanks & bulk containers
Above-ground storage tanks (AST) containing fuels, chemicals or hazardous substances are subject to DSEAR 2002, COMAH 2015 (where thresholds apply) and industry codes such as EEMUA 159.
Other assets in the industry Food & Beverage
Cold rooms & blast freezers
Every 12 months • F-Gas Reg. retained UK / EN 378
Steam boilers
Per WSE (typ. 14 to 26 months) • PSSR 2000
Food-grade autoclaves
Per WSE (typ. 26 to 40 months) • PSSR 2000
Conveyors & bottling lines
Every 12 months • PUWER 1998
Forklifts & pallet stackers
Every 12 months • LOLER 1998
CIP / SIP installations
Per HACCP plan • Retained EC 852/2004
Keep your assets fully compliant