Sprinkler systems
Statutory inspection, frequency and related regulatory watch
Everything you need to keep your sprinkler systems compliant: frequency, statutory reference, competent bodies, documents to produce and recommended regulatory watch.
Frequency
Weekly / monthly / annual
Statutory reference
BS EN 12845 / LPS 1048
Expected document
Inspection report + health & safety register
Main obligations
- Inspection weekly / monthly / annual is mandatory (BS EN 12845 / LPS 1048).
- Initial inspection when commissioning or re-commissioning after a significant modification.
- Maintain a health & safety register in line with applicable UK HSE regulations.
- Retain reports for at least 5 years, and for the full asset lifetime for the initial inspection.
- Close out defects promptly and keep an auditable trail of corrective actions.
What our software automates
- Schedule and early alerts (T-60, T-30, T-7) for every asset.
- Checklists aligned with applicable UK regulations, signed electronically on mobile.
- Asset identification via QR code or NFC tag attached to the equipment (document pouch).
- Automatic generation of timestamped PDF reports and defensible archive.
- Defect tracking, repair costs and full CMMS history.
- Automatic updates when regulations change (built-in regulatory watch).
Recommended regulatory watch
Category 1
Local Exhaust Ventilation (LEV) & workplace ventilation
COSHH reg. 9 requires that engineering controls provided to control exposure to hazardous substances — typically LEV systems — are examined and tested at suitable intervals. HSG258 sets out the industry-standard methodology for LEV thorough examination and test.
Category 2
Pressure systems (PSSR)
The Pressure Systems Safety Regulations 2000 (PSSR) require the user to have a Written Scheme of Examination (WSE) drawn up by a competent person covering all relevant parts of the system, and to ensure the system is examined in accordance with that scheme.
Other assets in the industry Warehousing
Pallet racking
Annual PRRS + weekly visual • SEMA / HSG76
Warehouse smoke ventilation
Every 12 months • BS 7346-8
Forklifts, VNA & pallet stackers
Every 12 months • LOLER 1998
AS/RS & stacker cranes
Every 12 months • BS EN 528
AGV and mobile robots
Every 12 months • ISO 3691-4
Industrial sectional doors
Every 12 months • BS EN 13241 / PUWER 1998
Keep your assets fully compliant