What is the statutory frequency of a Thorough Examination in the UK?
Frequency depends on the asset and the applicable regulation. As a guide: 6 months for equipment used to lift persons (MEWPs, suspended platforms) and for public passenger lifts under LOLER, 12 months for most load-lifting equipment (cranes, hoists), all lifting accessories and Category III fall-arrest PPE (PPE at Work Regs 2022), 3 months for certain heavy-use machinery under PUWER, and 12–72 months for pressure systems under the written scheme of examination (PSSR 2000). Frequency is shortened where use is intensive, the environment is harsh or after an incident. Cloud VGP calculates due dates automatically by asset family.
Who can carry out a Thorough Examination?
A Thorough Examination must be carried out by a competent person as defined in HSE guidance INDG422 and the relevant ACOPs. That can be an in-house appointed person, an independent competent person or an engineer surveyor from a UKAS-accredited body (a SAFed member such as Zurich, Allianz Engineering, HSB, Bureau Veritas or Applus+). Choice depends on the asset, the risk and, in some cases, on a specific requirement — for instance PSSR revalidation of a pressure vessel is generally carried out by a UKAS-accredited body. In every case, the person must have adequate practical and theoretical knowledge, appropriate measuring equipment and enough independence from the user. The competent person carries professional liability for the report.
What is the risk of not carrying out statutory examinations?
Under the Health and Safety at Work Act 1974 s.33 fines are unlimited and directors face up to 2 years' imprisonment. Sentencing Council guidelines set penalties by turnover: a Category A breach at a large employer can exceed £10m. Civil liability follows through personal injury claims. The HSE can serve improvement or prohibition notices requiring immediate withdrawal. Insurance cover for engineering breakdown or public liability may be void. Principal contractors in construction, industry and logistics require the reports as a condition of access.
How do I digitalise the statutory inspection register?
In four steps. First, build an up-to-date asset register with a unique identifier per asset (QR code or NFC tag). Second, define frequency and report templates per family, in line with the applicable regulation (LOLER, PUWER, PSSR). Third, run examinations on mobile — offline included — with photos, measurements, signatures and an auto-generated report. Fourth, track defects and corrective actions on a shared dashboard. A SaaS platform such as Cloud VGP handles the four steps on one platform, with no install, no lock-in and per-asset pricing (from £0.36 per asset per month, sliding scale).
Which documents should I prepare before an examination?
Before the engineer surveyor arrives, gather: the asset ID sheet (make, model, serial number, year, capacity), the manufacturer's manual and UKCA/CE declaration of conformity, the last Thorough Examination report and defect close-out history, the maintenance log, the H&S register, the competencies of the operators who use the asset. Also plan the access to the equipment (clearance, lighting, scaffold if needed), the PPE for the engineer surveyor and, for proof-load tests, the required test weights. Cloud VGP holds all of these in a digital asset log accessible via the asset's QR code.
How should I handle a defect raised during a Thorough Examination?
Grade every defect: existing (fix by the next due date), imminent (fix in a short window, typically 15 to 30 days), or defect becoming a danger to persons (immediate withdrawal from service). Each defect opens a corrective action assigned to a responsible person, with a due date and required evidence of close-out (photo, work order, invoice). The asset must not be returned to service without documented close-out. Cloud VGP automates the cycle: action opened on report close, owner notified, re-use lock until evidence is attached, full close-out history available at audit.
Do I need a fresh examination after a repair or modification?
Yes, in several scenarios. After a significant modification (structural change, replacement of a safety device, capacity change, transformation of the mounting), a post-modification examination is required (LOLER reg 9(3), PUWER reg 6). After a major repair or an incident (impact, overload, fall), a further examination is needed before return to service. After an extended out-of-service period (typically over three months), the same rule applies. These examinations do not replace the periodic one — they add to it. Cloud VGP automatically creates a post-modification examination the moment an operator logs a modification, major repair or incident.
How much does outsourcing Thorough Examinations cost?
Cost varies by asset type, location, complexity and the provider. As a guide: a simple lifting-accessory examination is £30–£60 excl. VAT, a forklift truck £80–£150, a MEWP £100–£200, a tower crane £400–£1,200 with a proof-load test. Travel is on top. Digitalisation reduces the total bill by optimising route planning, eliminating rekeying and industrialising report production. At £0.36 per asset per month, Cloud VGP costs less than a single annual outsourced examination of a lifting accessory.