Regulatory guide

    Electrical competence under EAWR 1989: the complete 2026 UK guide

    Electrical authorisation is a duty of the employer under the Electricity at Work Regulations 1989 (reg 16) and BS 7671 for any worker operating on, or in the vicinity of, an electrical installation. This guide sets out each category (Ordinary / Instructed / Skilled Person, LV and HV Authorised Persons, PV, testing and commissioning), refresher periods and how to automate tracking.

    8 categories aligned with BS 7671 / IET GN2
    Refresher recommended every 3 years
    Employer's criminal liability under EAWR

    What is electrical authorisation?

    Electrical authorisation is the employer's formal recognition that a person is competent to carry out a specified electrical task safely. It rests on three pillars: medical fitness, theoretical and practical training aligned to the target category, and an assessment of knowledge. It is recorded in writing — typically as an Authorisation to Work or Appointment under the site's Safety Rules — signed by the employer and the employee, and retained for the duration of employment.

    The category framework (Ordinary / Instructed / Skilled Person, LV and HV Authorised Persons) is defined in BS 7671 Part 2, IET Guidance Note 2 and the ENA competency schemes, made effective through EAWR 1989.

    Electrical authorisation categories

    Ordinary Person

    Non-electrical staff in an electrical area

    For staff who work close to electrical installations without operating on them (painters, bricklayers, cleaners, non-electrical maintenance). Under BS 7671 and EAWR reg 16, they must have basic electrical safety awareness and stay outside the vicinity zone of live parts.

    Instructed Person

    Advised or supervised by a Skilled Person

    Trained on specific tasks (fuse or lamp replacement, isolation of terminal circuits) up to 400 V AC, on protected final circuits. Works under the responsibility of a Skilled Person. Definitions align with BS 7671 Part 2 and IET GN2/GN3.

    Authorised Person (LV)

    Operational switching — LV

    Circuit breaker reset, disconnector operation, energising/de-energising equipment. Common authorisation for the operation of industrial and commercial installations.

    Competent Person (LV)

    General LV diagnostic and intervention

    Diagnosis, fault-finding, measurement, testing, terminal connection at low voltage (≤ 1000 V AC). The holder can work alone and supervise Instructed Persons. Essential for a general-purpose maintenance electrician (typically 18th-Edition trained, C&G 2391 tested).

    Authorised Person (HV)

    HV switching and access

    Under the site's Safety Rules (typically ENA G39 / SHE-based), the HV Authorised Person operates and issues Sanctions for Test and Permits to Work. HV skills follow ENA competency schemes and the Distribution Safety Rules.

    Senior Authorised Person (HV)

    HV isolation and permitry

    Carries out HV isolation, earthing, testing and issues Permits to Work. Central role for safety during outages, ultimately overseen by the site's Safety Rules Duty Holder.

    PV Competent Person

    Solar PV installations

    Specific competency for work on PV panels and inverters, required by the growth of commercial and industrial solar. Trained to BS 7671 Section 712 and MCS scheme requirements.

    Testing and Commissioning Engineer

    Test-bay and HV lab operations

    Reserved for test-bay or HV workshop operations under specific written procedures. Governed by the employer's Electrical Safety Rules and manufacturer procedures.

    Training & refresher

    Initial training: 1 to 3 days depending on category. Refresher recommended every 3 years by IET GN2 and the HSE. The employer must maintain competence on change of role, change of installation or any interruption longer than 6 months.

    Required records

    Named Authorisation to Work, training certificate, medical fitness statement, H&S register, isolation and lock-off procedures. All of these can be requested during an HSE inspection or an insurer's audit.

    Regulatory framework

    Electricity at Work Regulations 1989 · BS 7671 (18th Edition) · IET Guidance Notes 2 and 3 · ENA competency schemes · HSE HSR25.

    Responsibilities

    The employer issues, monitors and withdraws authorisations. The employee must respect the scope of their authorisation. An accident involving an unauthorised worker triggers the criminal liability of the duty holder under HSWA 1974 s.7 and EAWR reg 16.

    Track electrical competencies with Cloud VGP

    Our SaaS platform centralises Authorisations to Work across your teams, alerts before every refresher due date, archives certificates and produces the compliance tables the HSE and your insurers request.

    • Digital register of authorisations per employee and per site
    • Automatic alerts before expiry (90 / 30 / 7 days)
    • Archive of training certificates and medical statements
    • Multi-site EAWR compliance dashboard
    • HSE-ready PDF export for inspections and insurer audits

    Frequently asked questions

    Who authorises electrical competence in the UK?

    Under the Electricity at Work Regulations 1989 reg 16, no person shall be engaged in any work activity where technical knowledge or experience is necessary to prevent danger, unless they possess such knowledge or experience or are under such degree of supervision as may be appropriate. The duty to determine competence sits with the employer / duty holder. The employer records the appointment in writing — typically as an Authorisation to Work or Appointment under the Safety Rules — after suitable theoretical and practical training, an assessment and a favourable recommendation from the assessor. The training provider issues a certificate of achievement (e.g. C&G 2391, ENA competency scheme, HV switching authorisation); the authorisation itself is an act of the employer.

    How long is an electrical authorisation valid?

    EAWR does not fix a duration in days: it is the duty holder's responsibility. In practice, HSE guidance HSR25, IET Guidance Note 2, and the ENA competency schemes recommend a refresh every three years to maintain competence and integrate regulatory updates. Many employers set a shorter period, typically two years, for higher-risk levels (HV switching, HV isolation) or for very intermittent activity. Authorisation must be renewed immediately on change of role, an interruption longer than six months, a significant modification of the installations, or an incident linked to an operation. Authorisation is also withdrawn if the individual's medical fitness is called into question.

    What training does an Instructed Person need?

    Initial training is typically 1 to 2 days (7 to 14 hours) depending on the provider and audience. It covers theory (the nature of the electrical risk, effects of current on the human body, safe working distances, vicinity zones, response to an electrical accident, EAWR and BS 7671) and practice tailored to the future task (equipment recognition, distances, conduct in the presence of exposed live parts). It ends with a written and practical assessment, graded, with the assessor's recommendation. Refresher training runs for about a day. The provider issues a certificate; it is for the employer to decide whether to authorise on that basis.

    What is the difference between Ordinary Person, Instructed Person and Skilled Person?

    These three definitions are used in BS 7671 and IET Guidance Note 2. The Skilled Person (Electrically) has technical knowledge and experience to avoid the danger which electricity can create; the Instructed Person has been given adequate advice or supervision by a Skilled Person to enable them to avoid the danger; the Ordinary Person is neither Skilled nor Instructed. The Ordinary Person must not work in the vicinity of exposed live parts; the Instructed Person may perform prescribed tasks under supervision; the Skilled Person may work autonomously within the scope of their authorisation. The employer must make sure every task is allocated to a person of the appropriate category.

    Is electrical authorisation mandatory in the UK?

    Yes. EAWR reg 16 requires that every person carrying out or supervising electrical work possess the necessary technical knowledge or experience, or be under an appropriate degree of supervision. This applies at every voltage and to every type of operation (dead work, live work, testing, measurement, switching, non-electrical work in an electrical environment). A failure to authorise is a standalone criminal offence under HSWA 1974 s.33, independent of any accident, and engages the criminal liability of the duty holder. In the event of an accident, civil liability follows quickly through personal injury claims, and insurance cover may be void.

    How do I track electrical competencies across my workforce?

    Tracking must cover three things: the in-force authorisation (level, scope, dates), the underlying training certificates and refreshers, and any medical restrictions. A compliance platform such as Cloud VGP centralises these on a per-employee record, alerts 90, 30 and 7 days before every refresher due date, archives the PDFs, produces the compliance tables the HSE and insurers request, and blocks the release of a work order if the assigned individual does not hold the required authorisation. That last function is highly effective at preventing accidents and non-compliance during shared-site working.

    What is the risk of engaging unauthorised electrical staff?

    Risks accumulate. Under HSWA 1974 s.33, fines are unlimited and directors can face up to 2 years' imprisonment. Sentencing Council guidelines set penalties by turnover — a Category A high-culpability breach at a large organisation can exceed £10m. Civil liability follows through personal injury claims. The HSE can serve improvement or prohibition notices requiring immediate cessation. Insurance cover may be refused where the failure is documented. And most principal contractors and clients require production of authorisations as a condition of access to their sites.

    Does an authorisation from a previous employer remain valid?

    No, not automatically. Because the authorisation is an act of the employer, it lapses when the individual leaves the organisation that issued it. The new employer must assess the situation, check the in-date training certificates and, if satisfied, issue a fresh authorisation — possibly preceded by refresher training or a practical assessment. The same applies to agency workers, contractors and subcontractors: every user employer must ensure the individuals they engage hold a valid authorisation for the period and scope of the task. Cloud VGP tracks these transfers and re-authorisations.

    Can an employee refuse an electrical task on competence grounds?

    Yes, and they are expected to. The Employment Rights Act 1996 ss.44 and 100 protect employees who refuse to work in circumstances of danger they reasonably believe to be serious and imminent. An electrical task without adequate authorisation falls squarely within that protection. The employee alerts the employer, who must take the necessary steps (train, authorise, reorganise the task, engage a qualified party). No detriment or pay deduction may follow. The employer, in turn, can only assign an electrical task to a person effectively authorised.