Fire alarm system (BS 5839)
Statutory inspection, frequency and related regulatory watch
Everything you need to keep your fire alarm system (bs 5839) compliant: frequency, statutory reference, competent bodies, documents to produce and recommended regulatory watch.
Frequency
Every 6 months
Statutory reference
BS 5839-1 / RRO 2005
Expected document
Inspection report + health & safety register
Main obligations
- Inspection every 6 months is mandatory (BS 5839-1 / RRO 2005).
- Initial inspection when commissioning or re-commissioning after a significant modification.
- Maintain a health & safety register in line with applicable UK HSE regulations.
- Retain reports for at least 5 years, and for the full asset lifetime for the initial inspection.
- Close out defects promptly and keep an auditable trail of corrective actions.
What our software automates
- Schedule and early alerts (T-60, T-30, T-7) for every asset.
- Checklists aligned with applicable UK regulations, signed electronically on mobile.
- Asset identification via QR code or NFC tag attached to the equipment (document pouch).
- Automatic generation of timestamped PDF reports and defensible archive.
- Defect tracking, repair costs and full CMMS history.
- Automatic updates when regulations change (built-in regulatory watch).
Recommended regulatory watch
Category 5
Noise & hand-arm vibration
The Control of Noise at Work Regulations 2005 and the Control of Vibration at Work Regulations 2005 require duty holders to assess exposure, apply the hierarchy of control and monitor exposure at appropriate intervals.
Category 6
Construction — CDM inspections and scaffold checks
The Construction (Design and Management) Regulations 2015 impose duties on all dutyholders. Work at Height Regulations 2005 require scaffold and work-at-height equipment to be inspected before use and at set intervals.
Category 2
Pressure systems (PSSR)
The Pressure Systems Safety Regulations 2000 (PSSR) require the user to have a Written Scheme of Examination (WSE) drawn up by a competent person covering all relevant parts of the system, and to ensure the system is examined in accordance with that scheme.
Other assets in the industry Hospitality
Kitchen extract & canopies (TR/19)
Every 6 months • BESA TR/19
Commercial gas installations
Every 12 months • GSIUR 1998
Portable fire extinguishers
Annual + extended service • BS 5306-3
Smoke ventilation & AOV
Every 12 months • BS 7346-8
Hotel lifts
Every 6 months • LOLER 1998
Kitchen refrigeration
Every 12 months • F-Gas Reg. (retained UK)
Keep your assets fully compliant
Centralise inspections, automate due-date reminders and generate your statutory registers in one click. Personalised demo within 24 hours.